Fire Resistance Class: Determines the duration In accordace with the fire code; we offer fire door
of fire resistance which is determined as a result solutions for hospitals, dormitories, schools, shaft
of fire resistance tests specified in the European doors, high-rise building entrances, fire halls, etc.
Standards under appropriate heating and pressure According to the regulations the smoke and fire
conditions of a building. resistance rates can change from 30 minutes
to 120 minutes. 30 Minutes, 60 Minutes or 90
Fire resistance duration for ; Minutes fire resistance options are available
depending upon the situation, and place the door
a) 30-59 minutes are documented as EI30 is used.
b) 60-89 minutes are documented as EI60
c) 90-119 minutes are documented as EI90 Human safety & security comes before everything.
d) 120-149 minutes are documented as EI120 Fire resistant doors are instrumental in keeping
the fire under control, and have an important place
In addition to its own documents, offers service in minimizing possible damages and casualties.Fire
to the entire world with the Qmark / International doors keep the fire at a certain area, preventing it
Fire Door Manufacture to BS 476-22 document of from spreading to another section of the building,
BM TRADA, the most trusted institution in Europe, and decrease the risk factor for the residents in
the Middle East and in Turkey with the building by bringing the fire under control and
slowing down the spreading speed of the fire.
a) Qmark - FD30,
b) Qmark - FD60, Fire doors require expertise from the very
c) Qmark - FD90, beginning of the production to the final touches
d) Qmark - FD120 ratings. in the installation process. Each and every stage
of the production and installation has to be well in
The objective of the Fire Code is to provide hands of experts.
organization, training and supervision by taking
pre and post fire measures and by making it All of our fire doors are subjected to fire resistance
possible to put out any type of fire that might tests at internationally accredited testing
outbreak during creating, building, operating and laboratories, and certified with EI30 - EI60 - EI90
using processes in all kinds of constructions, Fire Resistance Certification.
buildings and facilities used by public and private
institutions & organizations and real persons. Documents. Following all these processes, serial
production process can be commenced. As Indoor
Fire resistand and smoke-proof wooden doors Life, if we have produced a model specific for your
are doors that isolate a room/living space from project, than we start the whole process from the
the room the fire may out break, and ensure the beginning and get a whole new certificate for your
safety and security of the people in the building specific model.
for a certain period of time.